File name: Pandora206s1_BuffaloNY_20231226_L2Fit_fwvt1c1d20220512p1-8.txt File generation date: 20240123T215823.8Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c1p1-8 Local principal investigator: Kang Sun Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 206 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora206_OF_v3d20211008.txt Instrument calibration file used: Pandora206s1_CF_v1d20220512.txt Level 1 file used: Pandora206s1_BuffaloNY_20231226_L1_smca1c1d20220512p1-8.txt Full location name: University at Buffalo Short location name: BuffaloNY Country of location: Canada Location latitude [deg]: 43.0015 Location longitude [deg]: -78.7869 Location altitude [m]: 190 Local noon date: 20231226 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1643 1792 Nominal wavelengths inside fitting window [nm]: 492.0358 492.1569 492.2779 492.3989 492.5200 492.6409 492.7619 492.8829 493.0038 493.1247 493.2456 493.3665 493.4874 493.6082 493.7291 493.8499 493.9707 494.0915 494.2123 494.3330 494.4537 494.5745 494.6952 494.8159 494.9365 495.0572 495.1778 495.2984 495.4190 495.5396 495.6602 495.7807 495.9013 496.0218 496.1423 496.2628 496.3832 496.5037 496.6241 496.7445 496.8649 496.9853 497.1057 497.2260 497.3463 497.4666 497.5869 497.7072 497.8275 497.9477 498.0679 498.1882 498.3083 498.4285 498.5487 498.6688 498.7889 498.9091 499.0291 499.1492 499.2693 499.3893 499.5093 499.6293 499.7493 499.8693 499.9893 500.1092 500.2291 500.3490 500.4689 500.5888 500.7086 500.8285 500.9483 501.0681 501.1879 501.3076 501.4274 501.5471 501.6668 501.7865 501.9062 502.0258 502.1455 502.2651 502.3847 502.5043 502.6239 502.7435 502.8630 502.9825 503.1020 503.2215 503.3410 503.4605 503.5799 503.6993 503.8187 503.9381 504.0575 504.1768 504.2962 504.4155 504.5348 504.6541 504.7733 504.8926 505.0118 505.1310 505.2502 505.3694 505.4886 505.6077 505.7268 505.8460 505.9650 506.0841 506.2032 506.3222 506.4412 506.5602 506.6792 506.7982 506.9172 507.0361 507.1550 507.2739 507.3928 507.5117 507.6305 507.7494 507.8682 507.9870 508.1058 508.2245 508.3433 508.4620 508.5807 508.6994 508.8181 508.9367 509.0554 509.1740 509.2926 509.4112 509.5298 509.6483 509.7668 509.8854 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20231226T134557.2Z 8760.573579 267 1 24.01 2 82.01 132.72 97.97 319.76 0.00 1 0.00 1 0 22 4.968e-03 4.955e-03 3.387e-03 3.371e-03 6.587819e+03 2.230024e+02 4.705809e+02 -6.000000e+00 2.729801e+02 273.67 -2.00 20.00 -2.00 505.24 0.00e+00 9.159356e-04 9.168308e-05 6.070707e-05 -6.000000e+00 1.378427e-04 273.67 -2.00 20.00 -2.00 500.20 0.00e+00 6.435437e-01 6.856804e-02 4.736417e-02 -6.000000e+00 9.997332e-02 222.72 -2.00 3.55 -2.00 501.82 0.00e+00 6.732 0.006 489.00 513.00 1 8.2878e+00 5.2454e-03 1.0359e-02 -6.0000e+00 7.6489e-03 2.3120e-02 1.3430e-03 1.2633e-03 -6.0000e+00 1.9823e-03 1.7998e-04 5.8564e-05 3.4925e-04 5.9415e-05 -6.0000e+00 5.4618e-04 1.0558e-02 -3.4832e-05 12 8 8 10 0 0 86.18 18.11 2.18 0.01056 0.01096 6 6 2 2 0 4000.000 15.00 18.11 14.83 21.58 21.48 19.7 982.18 -673 -435 -153 508 -200 -154 753 974 405 468 -211 310 -373 -332 -199 -718 87 -642 512 154 222 208 203 -324 277 191 330 -1020 -100 -423 -490 -395 -816 1196 -54 650 -50 470 190 -26 64 -134 116 -60 558 551 749 741 -418 -230 -695 -873 -442 -819 -686 -182 143 346 -179 788 450 215 124 608 88 206 -574 115 -169 -272 171 -219 -815 45 -218 -369 91 -98 -839 -272 -335 -519 40 -250 -303 79 -187 734 -381 -517 515 387 -131 1078 -149 -250 766 25 57 -452 -781 -544 -790 -1039 1434 -696 55 -738 -138 -679 562 -188 1031 601 290 259 317 385 615 153 37 192 -351 24 26 155 406 645 922 91 -2 269 -1090 321 -137 -571 -43 -418 -59 -249 32 793 85 -307 -597 -135 353 308 -464 37 -658 -428 -155 526 -208 -163 805 1050 439 502 -225 324 -387 -340 -203 -736 90 -680 549 168 244 228 216 -348 296 205 352 -1088 -107 -441 -502 -405 -854 1262 -58 693 -53 495 198 -27 67 -140 122 -64 596 591 798 780 -437 -235 -692 -879 -438 -819 -677 -184 147 359 -188 817 469 225 131 635 92 212 -586 114 -167 -266 165 -213 -803 45 -217 -367 89 -95 -804 -258 -318 -497 38 -242 -298 78 -185 721 -367 -498 494 376 -129 1050 -145 -238 726 24 52 -406 -702 -495 -743 -986 1365 -685 54 -718 -133 -657 543 -186 1015 599 282 254 313 381 605 149 35 182 -331 23 24 147 383 607 863 86 -2 256 -1035 298 -128 -526 -40 -398 -57 -244 31 780 82 -299 -582 -130 343 294 -439 35 SQ 20231226T160333.8Z 8760.669142 344 1 27.47 2 68.41 162.21 108.70 347.51 0.00 1 0.00 1 0 15 6.654e-03 6.661e-03 5.123e-03 5.078e-03 3.812288e+03 3.244895e+02 2.837632e+02 -6.000000e+00 3.655891e+02 273.67 -2.00 20.00 -2.00 505.20 0.00e+00 8.141293e-04 1.387298e-04 4.591841e-05 -6.000000e+00 1.846419e-04 273.67 -2.00 20.00 -2.00 499.98 0.00e+00 2.168796e-01 1.049114e-01 2.699446e-02 -6.000000e+00 1.339475e-01 222.72 -2.00 3.55 -2.00 501.63 0.00e+00 2.693 0.000 489.00 513.00 1 9.1907e+00 8.0246e-03 4.5440e-03 -6.0000e+00 1.0247e-02 1.9653e-02 2.0645e-03 6.8695e-04 -6.0000e+00 2.6572e-03 1.3296e-04 1.2736e-03 5.3358e-04 3.7545e-05 -6.0000e+00 7.3141e-04 1.1428e-02 -7.2115e-05 12 8 8 10 0 0 0.46 18.10 1.69 0.01143 0.02026 19 19 1 2 0 1445.720 15.00 18.10 17.08 21.58 21.48 20.0 997.74 -1542 -713 -1072 -600 -176 356 819 721 960 772 758 -154 -631 -53 -385 -2174 187 -172 -429 -4 1458 315 -176 764 -13 131 575 483 273 -1461 -773 -254 -1209 1064 708 -343 744 -156 884 -734 838 -240 108 -142 -215 389 365 256 -663 -305 1 -557 -716 244 -381 607 92 356 91 1257 -145 -89 361 846 450 -449 -589 -442 -7 20 688 -100 -419 -554 -19 -281 -328 -347 -927 214 -322 48 -76 -150 0 346 -48 151 -142 -106 245 544 171 89 -80 -709 1133 838 474 -774 -609 -1126 -690 -369 1615 -296 -652 -628 -99 -74 -26 83 948 1191 -618 -400 981 1182 162 333 127 -446 -436 -954 147 -834 656 233 -77 54 1777 -634 -780 -44 -162 -360 113 219 -822 295 470 749 -72 1530 -939 454 -203 -1558 -351 -686 -1547 -717 -1110 -638 -192 395 918 817 1084 866 837 -169 -686 -56 -410 -2361 201 -189 -463 -4 1577 345 -194 835 -14 145 628 522 289 -1530 -790 -258 -1262 1117 765 -378 809 -170 939 -786 882 -257 116 -155 -236 426 397 276 -708 -316 1 -551 -701 238 -382 619 97 377 97 1320 -148 -91 370 860 456 -454 -586 -433 -7 19 673 -94 -401 -537 -18 -272 -313 -327 -868 197 -299 44 -71 -142 0 333 -47 146 -137 -103 239 534 170 89 -79 -694 1063 769 427 -694 -543 -1023 -642 -354 1556 -282 -619 -590 -92 -69 -25 79 905 1144 -608 -395 959 1154 159 322 121 -421 -409 -901 138 -791 613 218 -72 50 1617 -582 -708 -39 -144 -326 104 204 -785 282 452 721 -68 1418 -890 421 -186 -1421 -323 -606 SQ 20231226T173809.5Z 8760.734832 395 1 24.01 2 66.56 185.62 109.24 8.60 0.00 1 0.00 1 0 15 3.790e-03 3.768e-03 2.301e-03 2.291e-03 3.599397e+03 1.424162e+02 2.743318e+02 -6.000000e+00 2.082543e+02 273.66 -2.00 20.00 -2.00 505.21 0.00e+00 5.341116e-04 6.242856e-05 3.303320e-05 -6.000000e+00 1.051756e-04 273.66 -2.00 20.00 -2.00 500.19 0.00e+00 2.228767e-01 4.658441e-02 2.465392e-02 -6.000000e+00 7.629632e-02 222.73 -2.00 3.55 -2.00 501.82 0.00e+00 2.495 0.000 489.00 513.00 1 8.3239e+00 3.5707e-03 4.1571e-03 -6.0000e+00 5.8371e-03 1.2896e-02 9.1798e-04 6.4953e-04 -6.0000e+00 1.5134e-03 3.2643e-04 1.2600e-03 2.4236e-04 3.6442e-05 -6.0000e+00 4.1666e-04 1.1305e-02 -6.2828e-05 10 0 0 10 0 0 99.58 18.11 2.19 0.01131 0.02004 6 6 2 2 0 4000.000 15.00 18.11 16.90 21.58 21.48 20.2 997.17 -885 -312 -401 -355 19 404 516 480 376 198 288 -60 -298 -383 -203 -128 -178 -292 -11 112 318 449 317 64 257 266 141 -48 -214 -287 -565 -567 -577 117 331 386 181 158 272 -435 -34 -55 79 -142 16 481 469 814 169 -513 -660 -321 -534 -778 -170 271 15 232 116 850 138 632 412 397 64 213 -310 -331 182 -134 -86 -227 -334 -464 6 -139 46 -226 -408 -227 -237 -451 -130 -314 -281 -205 191 -164 -123 93 -295 656 149 780 195 269 295 77 -66 -686 -669 -409 -519 -487 1086 -132 302 -367 -126 -275 333 -192 557 771 332 93 154 399 440 -392 -208 -121 -794 -204 -84 7 23 522 42 335 514 -377 -97 33 -134 44 188 4 -215 292 341 376 -167 515 29 238 -699 -91 -386 -831 -888 -315 -403 -368 20 424 549 516 404 212 303 -62 -316 -401 -210 -133 -188 -306 -11 121 344 487 344 69 280 291 153 -51 -226 -294 -571 -573 -593 123 355 407 191 170 289 -460 -36 -58 82 -148 17 506 491 839 177 -529 -663 -314 -517 -760 -168 275 15 237 118 862 141 644 422 406 66 214 -308 -334 181 -132 -84 -222 -330 -464 6 -135 45 -219 -393 -217 -227 -436 -127 -300 -271 -199 185 -160 -120 91 -291 648 149 778 194 263 281 71 -62 -638 -621 -384 -487 -472 1062 -128 290 -351 -122 -269 318 -186 544 758 330 93 155 400 439 -389 -203 -117 -763 -195 -80 6 22 497 40 317 483 -353 -89 30 -122 40 175 4 -208 277 325 361 -162 497 29 229 -666 -87 -363 -780 SQ 20231226T180105.1Z 8760.750754 406 1 3.86 2 67.17 191.30 108.47 13.65 0.00 1 0.00 1 0 15 3.012e-03 3.009e-03 1.222e-03 1.218e-03 2.915431e+03 7.393491e+01 2.191746e+02 -6.000000e+00 1.654863e+02 273.66 -2.00 20.00 -2.00 505.22 0.00e+00 5.448305e-04 3.312995e-05 3.444429e-05 -6.000000e+00 8.358264e-05 273.66 -2.00 20.00 -2.00 500.24 0.00e+00 2.235486e-01 2.462330e-02 2.161013e-02 -6.000000e+00 6.064678e-02 222.73 -2.00 3.55 -2.00 501.86 0.00e+00 2.557 0.000 489.00 513.00 1 5.2436e+00 1.8852e-03 4.1012e-03 -6.0000e+00 4.6394e-03 1.4464e-02 4.8602e-04 5.5994e-04 -6.0000e+00 1.2035e-03 7.0517e-03 1.2858e-03 1.2921e-04 3.1009e-05 -6.0000e+00 3.3104e-04 1.4405e-02 -1.1463e-04 12 1 1 12 1 1 46.21 18.11 2.20 0.01441 0.02332 7 56 1 2 0 482.390 15.00 18.11 18.15 21.58 21.48 20.2 1005.32 -524 -558 -302 93 217 102 534 648 466 470 158 -127 -68 -182 -254 -321 -318 -246 -115 268 362 132 195 243 384 172 -13 60 -172 -303 -352 -346 -256 70 62 223 219 88 395 -88 60 -11 57 172 267 322 201 157 -159 -307 -645 -558 -854 -594 -485 -279 47 229 50 436 497 546 301 15 292 258 21 -158 6 -220 -264 -360 -203 -56 -26 -82 -283 -329 -266 -166 -400 -509 -83 -173 -58 -33 95 -83 78 -245 -9 83 289 206 306 133 139 104 -255 -362 -498 -664 -435 -193 -107 -201 -65 -327 -441 -123 184 91 267 461 422 446 650 344 312 75 234 141 -131 287 95 -128 219 283 138 -28 415 126 -252 -203 -146 -235 235 -1 104 367 357 116 124 80 73 -50 -161 -307 -385 -615 -526 -565 -307 95 228 107 570 697 502 502 166 -132 -71 -188 -262 -332 -326 -258 -123 283 385 141 208 259 411 184 -14 63 -178 -311 -356 -349 -263 72 66 238 233 93 411 -91 62 -11 60 182 278 336 209 165 -164 -310 -650 -549 -849 -592 -482 -279 48 236 52 449 512 552 306 15 295 262 21 -157 6 -217 -258 -353 -200 -55 -25 -81 -275 -321 -256 -159 -385 -494 -81 -167 -57 -33 94 -82 76 -238 -9 82 287 205 302 129 136 98 -242 -339 -464 -628 -414 -185 -106 -195 -64 -319 -427 -119 180 89 262 456 420 446 640 340 306 74 227 136 -125 274 91 -124 210 271 132 -26 392 120 -237 -189 -136 -221 224 -1 100 351 344 112 121 78 72 -49 -154 -294 -362 -577