File name: Pandora219s1_Ilocos_20240922_L2Fit_fsus1c3d20240215p1-8.txt File generation date: 20240924T113753.4Z Data description: Level 2 spectral fitting results file Data file version: fsus1c3p1-8 Local principal investigator: Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 219 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora219_OF_v1d20220124.txt Instrument calibration file used: Pandora219s1_CF_v3d20240215.txt Level 1 file used: Pandora219s1_Ilocos_20240922_L1_smca1c3d20240215p1-8.txt Full location name: Mariano Marcos State University Short location name: Ilocos Country of location: Philippines Location latitude [deg]: 18.0582 Location longitude [deg]: 120.5451 Location altitude [m]: 34 Local noon date: 20240922 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OOB session based on lab session 101 First and last pixel inside fitting window: 193 337 Nominal wavelengths inside fitting window [nm]: 306.0583 306.1995 306.3407 306.4818 306.6230 306.7642 306.9053 307.0464 307.1876 307.3287 307.4698 307.6109 307.7519 307.8930 308.0341 308.1751 308.3161 308.4572 308.5982 308.7392 308.8802 309.0211 309.1621 309.3031 309.4440 309.5849 309.7258 309.8667 310.0076 310.1485 310.2894 310.4303 310.5711 310.7119 310.8528 310.9936 311.1344 311.2752 311.4159 311.5567 311.6975 311.8382 311.9789 312.1197 312.2604 312.4011 312.5418 312.6824 312.8231 312.9637 313.1044 313.2450 313.3856 313.5262 313.6668 313.8074 313.9480 314.0885 314.2291 314.3696 314.5101 314.6506 314.7911 314.9316 315.0721 315.2126 315.3530 315.4935 315.6339 315.7743 315.9147 316.0551 316.1955 316.3359 316.4762 316.6166 316.7569 316.8972 317.0375 317.1778 317.3181 317.4584 317.5987 317.7389 317.8792 318.0194 318.1596 318.2998 318.4400 318.5802 318.7204 318.8605 319.0007 319.1408 319.2809 319.4210 319.5611 319.7012 319.8413 319.9814 320.1214 320.2615 320.4015 320.5415 320.6815 320.8215 320.9615 321.1014 321.2414 321.3814 321.5213 321.6612 321.8011 321.9410 322.0809 322.2208 322.3606 322.5005 322.6403 322.7802 322.9200 323.0598 323.1996 323.3393 323.4791 323.6189 323.7586 323.8984 324.0381 324.1778 324.3175 324.4572 324.5968 324.7365 324.8761 325.0158 325.1554 325.2950 325.4346 325.5742 325.7138 325.8534 325.9929 326.1325 326.2720 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------