File name: Pandora164s1_Seosan_20231112_L2Fit_fout2c14d20211028p1-8.txt File generation date: 20231112T152601.8Z Data description: Level 2 spectral fitting results file Data file version: fout2c14p1-8 Local principal investigator: Jinsoo Park Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 164 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora164_OF_v1d20201014.txt Instrument calibration file used: Pandora164s1_CF_v14d20211028.txt Level 1 file used: Pandora164s1_Seosan_20231112_L1_smca1c14d20211028p1-8.txt Full location name: Institute of Atmospheric Environment, Chungcheong Province Short location name: Seosan Country of location: Korea, Republic of Location latitude [deg]: 36.7769 Location longitude [deg]: 126.4938 Location altitude [m]: 25 Local noon date: 20231112 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 235 377 Nominal wavelengths inside fitting window [nm]: 305.0326 305.1736 305.3147 305.4558 305.5968 305.7378 305.8789 306.0199 306.1608 306.3018 306.4428 306.5837 306.7247 306.8656 307.0065 307.1474 307.2882 307.4291 307.5700 307.7108 307.8516 307.9924 308.1332 308.2740 308.4148 308.5555 308.6963 308.8370 308.9777 309.1184 309.2591 309.3997 309.5404 309.6810 309.8217 309.9623 310.1029 310.2435 310.3841 310.5246 310.6652 310.8057 310.9462 311.0867 311.2272 311.3677 311.5082 311.6486 311.7891 311.9295 312.0699 312.2103 312.3507 312.4911 312.6315 312.7718 312.9121 313.0525 313.1928 313.3331 313.4733 313.6136 313.7539 313.8941 314.0343 314.1746 314.3148 314.4549 314.5951 314.7353 314.8754 315.0156 315.1557 315.2958 315.4359 315.5760 315.7161 315.8561 315.9962 316.1362 316.2762 316.4162 316.5562 316.6962 316.8362 316.9761 317.1161 317.2560 317.3959 317.5358 317.6757 317.8156 317.9554 318.0953 318.2351 318.3750 318.5148 318.6546 318.7944 318.9341 319.0739 319.2136 319.3534 319.4931 319.6328 319.7725 319.9122 320.0519 320.1915 320.3312 320.4708 320.6104 320.7500 320.8896 321.0292 321.1688 321.3083 321.4479 321.5874 321.7269 321.8664 322.0059 322.1454 322.2849 322.4243 322.5638 322.7032 322.8426 322.9820 323.1214 323.2608 323.4002 323.5395 323.6789 323.8182 323.9575 324.0968 324.2361 324.3754 324.5147 324.6539 324.7932 324.9324 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Columns 100-242: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 243-385: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20231112T040334.6Z 8716.169150 265 1 49.55 2 55.43 193.19 57.21 210.75 0.00 1 0.00 1 0 17 5.234e-02 1.365e-02 3.298e-02 8.620e-03 2.536054e-01 4.239515e-03 3.000973e-03 -6.000000e+00 2.916779e-02 224.37 -2.00 3.43 -2.00 317.88 0.00e+00 6.020416e-04 7.118730e-04 1.914067e-04 -6.000000e+00 1.307017e-03 284.00 -2.00 20.00 -2.00 317.13 0.00e+00 1.757 0.000 302.00 328.00 3 6.2599e+00 1.1265e-02 2.1578e-02 -6.0000e+00 7.1922e-02 5.6420e-02 1.2795e-02 1.2587e-02 -6.0000e+00 7.8186e-02 1.4019e-03 7.9440e-03 6.2870e-03 -6.0000e+00 4.6736e-02 -4.8035e-03 4.0475e-03 1.8729e-03 -6.0000e+00 2.0194e-02 1.2575e-04 1.4735e-03 2.4418e-04 1.9679e-05 -6.0000e+00 1.3427e-03 -9.6422e-03 3.6285e-04 12 9 8 11 8 0 99.97 22.88 0.50 -0.00964 0.00143 13 3 1 5 0 3810.840 25.90 20.00 22.88 13.47 35.8 922.40 9269 -12125 6232 -4565 -23020 -26650 -1871 4408 -7080 10326 -18527 -5102 26310 1740 1055 -4625 1634 -678 3747 3735 8485 8179 544 15798 -5457 3583 -4013 144 6117 -1276 -210 -5146 4015 -6190 -1345 -5449 -6715 927 726 3577 -2473 -328 -1186 -1851 2828 -4474 -1139 -1684 4570 -2593 683 2378 -1551 2075 449 1855 2295 452 2200 1007 -180 200 3195 2435 549 1094 -632 -159 128 3370 1473 -1472 -231 1272 -1 144 -415 -3885 -935 -2028 -1203 -2134 -1491 -1578 -2085 229 1049 -1531 592 501 1397 757 300 837 -2871 609 -1209 2055 590 199 -1048 523 -1186 -3121 291 -2526 -17 -1198 448 736 1260 284 -840 603 -600 -209 327 -77 42 -142 1207 -192 476 -459 1961 295 -904 2428 378 361 375 200 1345 -229 -119 -1251 825 101 398 -1591 213 -379 -555 723 -1306 587 -461 -2451 -2713 -155 382 -772 1026 -2419 -578 2422 234 163 -850 297 -130 718 740 1646 1577 114 3017 -1352 848 -1040 34 1258 -271 -47 -1289 998 -1805 -352 -1398 -1871 275 258 1466 -1192 -162 -611 -975 1418 -2411 -587 -847 2119 -1278 341 1255 -898 1224 279 1156 1454 292 1368 625 -115 136 2293 1892 442 816 -440 -106 88 2544 1252 -1353 -212 1113 -1 108 -282 -2554 -610 -1497 -990 -1960 -1461 -1610 -2272 262 1257 -1947 745 615 1583 790 288 758 -2805 631 -1409 2574 803 271 -1363 620 -1330 -3613 355 -3355 -23 -1707 657 1141 2057 477 -1388 923 -854 -276 423 -103 60 -219 1889 -301 728 -682 2703 395 -1161 2983 503 515 562 310 2082 -371 -202 -2272 1509 189 756 -3009 383 -663 -944 SS 20231112T042214.3Z 8716.182110 281 1 0.48 2 56.45 198.41 59.27 215.36 0.00 1 0.00 1 0 17 1.243e-02 6.816e-03 7.048e-03 3.403e-03 2.555485e-01 1.690189e-03 3.064421e-03 -6.000000e+00 6.918745e-03 224.37 -2.00 3.43 -2.00 316.19 0.00e+00 -4.897772e-05 1.897460e-04 4.705531e-05 -6.000000e+00 3.102111e-04 283.99 -2.00 20.00 -2.00 315.50 0.00e+00 1.804 0.000 302.00 328.00 3 1.5554e+00 4.3592e-03 2.1991e-02 -6.0000e+00 1.7060e-02 2.0698e-03 4.8893e-03 1.2659e-02 -6.0000e+00 1.8553e-02 -1.9864e-03 2.8407e-03 6.2913e-03 -6.0000e+00 1.1090e-02 -1.8854e-03 1.3468e-03 1.7933e-03 -6.0000e+00 4.7876e-03 1.3650e-02 7.8182e-04 9.2282e-05 2.0801e-05 -6.0000e+00 3.1897e-04 -1.0143e-02 3.8261e-05 12 9 1 12 9 1 -125.18 22.88 0.28 -0.01014 -0.00427 3 84 1 5 0 117.400 25.90 20.00 22.88 13.81 35.7 924.65 -2185 -2972 -2084 -894 -4734 3003 -7752 -1801 -686 -1808 264 -1530 1526 -789 1115 -1341 740 2141 781 803 660 514 1171 971 1252 325 2018 -1344 824 790 1233 -784 1386 906 -2119 504 -2509 -1015 -1094 -1027 -582 -1224 -398 -1250 -164 -217 -49 102 -1101 392 280 976 334 1336 1059 586 916 398 558 859 947 1113 615 2174 809 -711 369 -394 -489 164 269 593 -45 -489 315 -204 -569 -48 214 -345 -899 -546 -1937 -1914 -954 -691 -798 -733 716 -171 -10 472 598 801 146 432 920 313 271 -464 -404 -651 -665 316 -676 -1040 -524 -341 -305 148 177 134 451 130 367 149 911 122 -17 130 -631 -460 470 263 387 926 139 1159 1149 374 548 38 221 -491 101 -51 -315 330 -126 -686 -407 -197 -538 -398 -598 -430 -177 -866 485 -1423 -346 -145 -409 58 -341 361 -212 329 -439 247 726 276 291 244 189 432 376 504 136 844 -553 315 294 475 -324 599 408 -933 210 -1126 -497 -608 -640 -386 -840 -277 -883 -115 -152 -34 70 -746 262 193 703 250 1030 836 469 743 324 448 684 764 934 544 1993 755 -639 313 -329 -419 151 264 597 -46 -488 301 -184 -484 -39 177 -307 -862 -555 -2069 -2095 -1078 -814 -970 -910 886 -210 -11 524 631 819 154 481 1083 394 354 -607 -511 -788 -773 369 -836 -1332 -686 -457 -420 210 260 200 659 183 492 193 1163 159 -23 184 -913 -661 664 364 520 1210 177 1460 1500 511 770 55 319 -724 153 -80 -501 530 -204 -1102 -641 -304 -818 SS 20231112T043135.5Z 8716.188605 287 1 51.78 2 57.09 200.96 60.39 217.58 0.00 1 0.00 1 0 25 9.115e-03 5.140e-03 1.090e-03 2.890e-04 2.572032e-01 1.420776e-04 3.081559e-03 -6.000000e+00 5.070256e-03 224.37 -2.00 3.43 -2.00 317.73 0.00e+00 1.171070e-04 2.327086e-05 6.251899e-05 -6.000000e+00 2.273713e-04 283.99 -2.00 20.00 -2.00 316.98 0.00e+00 1.834 0.000 302.00 328.00 3 7.6257e-01 3.7656e-04 2.2355e-02 -6.0000e+00 1.2502e-02 -7.9013e-03 4.2665e-04 1.2902e-02 -6.0000e+00 1.3600e-02 5.4132e-03 2.6563e-04 6.4101e-03 -6.0000e+00 8.1296e-03 -5.9966e-03 1.3566e-04 1.8287e-03 -6.0000e+00 3.5061e-03 2.9272e-02 -1.4504e-04 8.1401e-06 2.0376e-05 -6.0000e+00 2.3395e-04 -5.1130e-03 1.3950e-06 10 0 0 10 0 0 99.99 22.88 0.23 -0.00511 -0.00620 2088 410 1 5 0 24.010 25.90 20.00 22.88 13.99 35.8 926.28 -2624 -2121 -2202 -2235 -3550 -2671 -2572 -1001 -548 -597 -1571 -2099 -1168 -1439 -389 23 -242 422 75 697 168 36 731 451 159 127 681 81 8 389 1007 760 1000 312 -1710 -1550 -1777 -1706 -1104 -642 -951 -1013 -577 -698 -298 -279 -398 -222 -493 -128 703 704 836 1035 690 753 927 635 685 597 807 1086 1110 1410 505 -52 253 -283 355 579 97 140 -40 267 119 212 253 -295 44 -282 -883 -872 -1769 -1613 -1100 -867 -618 -338 192 97 227 546 391 745 779 466 462 738 144 -397 -261 -516 -543 26 -342 -913 -654 -675 -433 33 227 164 14 91 -46 261 369 251 211 35 -411 -152 156 168 473 626 387 1169 882 489 415 174 -68 -47 37 -91 -213 186 -150 -434 -239 -320 -320 -229 -206 -223 -217 -306 -212 -234 -100 -56 -66 -174 -232 -142 -202 -62 4 -45 81 15 144 36 8 155 101 38 32 171 19 2 91 246 183 260 87 -454 -427 -529 -532 -412 -284 -468 -522 -306 -376 -159 -149 -209 -113 -247 -64 363 391 491 641 445 494 622 428 451 388 534 767 854 1166 428 -41 182 -197 256 475 89 135 -39 249 104 167 178 -196 30 -216 -769 -843 -1703 -1615 -1170 -992 -745 -421 241 118 255 560 399 719 785 478 526 934 198 -542 -335 -611 -597 29 -419 -1194 -890 -964 -646 52 352 259 22 141 -66 345 480 340 306 55 -665 -243 243 252 667 842 494 1461 1180 707 633 274 -110 -77 59 -156 -376 336 -275 -782 -413 -535 -518 SS 20231112T043701.9Z 8716.192383 290 1 0.33 2 57.49 202.43 61.07 218.83 0.00 1 0.00 1 0 17 1.511e-02 7.026e-03 9.158e-03 4.221e-03 2.604061e-01 2.094140e-03 3.106534e-03 -6.000000e+00 8.409175e-03 224.37 -2.00 3.43 -2.00 316.32 0.00e+00 3.379270e-05 2.421548e-04 4.965901e-05 -6.000000e+00 3.770803e-04 283.99 -2.00 20.00 -2.00 315.62 0.00e+00 1.854 0.000 302.00 328.00 3 1.4443e+00 5.4114e-03 2.2523e-02 -6.0000e+00 2.0735e-02 -9.4539e-03 6.0718e-03 1.2876e-02 -6.0000e+00 2.2553e-02 1.3552e-03 3.5379e-03 6.3942e-03 -6.0000e+00 1.3481e-02 -2.1263e-03 1.6903e-03 1.8220e-03 -6.0000e+00 5.8168e-03 1.4462e-02 2.2518e-04 1.1491e-04 2.0816e-05 -6.0000e+00 3.8786e-04 -7.0454e-03 4.2590e-05 12 9 1 12 1 1 999.00 22.89 0.32 -0.00705 -0.00535 2 91 1 5 0 107.920 25.90 20.00 22.89 14.33 35.9 929.53 -854 -3231 3198 -3075 1883 -9073 -5214 1069 -287 5228 -688 483 -3236 -2915 -571 924 1564 1014 1524 174 1492 861 1621 1419 -515 1400 72 520 43 1514 1252 593 2861 -732 -1278 -4175 -3179 -1003 -260 -912 -1252 -654 -1438 -921 -770 -1749 1949 -1484 236 -1617 379 896 44 2219 385 1178 835 1075 228 351 1044 693 1541 816 958 -687 -224 199 -367 1521 -80 1199 134 233 679 25 568 -1120 -352 -1101 -637 -1062 -1591 -856 -1339 -282 -590 -491 298 368 371 -21 -567 -81 131 405 361 344 158 30 221 -658 -755 53 -315 -605 -92 -808 -693 342 416 187 41 376 -37 -96 -187 274 391 -175 174 -384 240 153 206 352 486 1222 928 616 -99 648 -395 -267 345 -372 84 81 -292 -26 -810 128 -520 -144 -611 595 -582 307 -1525 -882 189 -57 1056 -145 100 -754 -758 -162 284 498 333 514 61 527 304 574 528 -203 561 30 204 16 542 467 236 1189 -325 -545 -1748 -1396 -479 -140 -555 -816 -438 -989 -637 -531 -1215 1312 -1003 156 -1077 257 636 33 1678 301 929 669 862 181 276 831 576 1342 747 886 -613 -189 164 -311 1381 -78 1195 135 230 646 23 477 -913 -291 -979 -607 -1079 -1692 -929 -1512 -330 -715 -607 369 448 434 -24 -601 -84 138 451 427 432 208 39 279 -800 -881 63 -389 -775 -121 -1089 -959 487 612 279 60 532 -49 -125 -241 361 533 -250 253 -555 342 214 279 464 622 1547 1220 845 -141 932 -576 -396 527 -588 134 131 -479 -42 -1288 199 -797 SS 20231112T072605.8Z 8716.309790 393 1 50.09 2 79.81 238.74 88.30 249.31 0.00 1 0.00 1 0 25 5.117e-01 7.369e-03 2.634e-01 4.235e-03 7.181874e-01 2.321641e-03 7.870602e-03 -6.000000e+00 2.880686e-01 224.36 -2.00 3.43 -2.00 321.68 0.00e+00 3.145586e-03 1.259427e-03 1.051076e-03 -6.000000e+00 1.292425e-02 283.98 -2.00 20.00 -2.00 321.15 0.00e+00 5.417 0.003 302.00 328.00 3 1.1637e+00 8.6024e-03 6.6033e-02 -6.0000e+00 7.1193e-01 7.2625e-02 1.2708e-02 4.0490e-02 -6.0000e+00 7.7520e-01 -1.0005e-01 1.3630e-02 2.1061e-02 -6.0000e+00 4.5976e-01 2.8682e-02 6.3223e-03 8.1800e-03 -6.0000e+00 1.9697e-01 3.6617e-04 -6.2755e-04 1.1799e-04 8.6586e-05 -6.0000e+00 1.3338e-02 -5.5831e-03 6.2363e-05 11 8 0 10 0 0 70.92 22.88 0.39 -0.00558 -0.01030 128 25 1 5 0 391.210 25.90 19.99 22.88 11.77 35.7 912.79 -232603 -182476 -163448 -145966 -44855 -180842 900000 -244755 900000 -146732 -121384 -123884 -115505 -91623 96202 -67889 -92896 -23193 -53242 -43258 -29099 -75316 22267 -21564 -29861 -77459 -15432 -29916 -13527 -15161 -38265 -23902 -27984 -8971 -2487 -9241 2385 -555 382 899 -4178 -9063 -117 12160 -666 12771 -3810 625 4131 6886 -3844 3281 1449 747 9830 612 5279 3081 2566 2820 749 6402 -413 1043 3159 1160 3110 -221 1585 1502 2017 2818 1267 4525 88 1273 -2137 -123 -2239 1039 -1130 -2049 -769 -1132 -125 -2049 205 -729 565 2420 -335 1481 -698 -254 -60 119 569 169 -13 -287 49 -572 -1273 -295 -1853 -1381 -1936 -583 -689 -58 212 -17 690 324 493 151 366 183 -130 -397 -455 17 106 -87 572 528 498 663 1134 -18 566 318 56 110 -237 -274 -454 107 -177 -233 224 41 30 -1746 -1027 -859 -657 -185 -1018 900000 -3215 900000 -936 -638 -744 -824 -688 397 -662 -1360 -192 -659 -520 -317 -1300 150 -251 -415 -1861 -209 -460 -173 -211 -819 -547 -798 -239 -61 -232 58 -16 14 40 -227 -565 -7 680 -43 743 -270 44 301 525 -366 333 166 95 1232 88 757 454 369 394 109 964 -77 220 713 264 687 -52 402 408 613 898 409 1461 27 346 -555 -32 -654 354 -467 -909 -376 -590 -69 -1232 127 -470 362 1476 -196 794 -401 -148 -36 83 464 161 -14 -311 50 -528 -1054 -237 -1632 -1286 -1905 -608 -789 -74 307 -27 1091 502 723 212 511 266 -201 -647 -738 27 157 -126 784 701 636 867 1679 -32 1073 651 120 253 -589 -720 -1222 291 -485 -616 553 95 67